Vehicle Storage
Bloom Engineers & Associates Project Examples
City of St. Paul - St. Paul, Minnesota
Southwest Maintenance Facility:
- Construct a new maintenance facility for the Parks and Recreation Department consisting of an Office area, heated service area, cold storage area, chemical mixing facility, outdoor wash bay, and fuel station.
- Mechanical systems consist of the following:
- Water booster pump system to provide sufficient pressure to plumbing fixtures and wash down equipment
- Waste from plumbing fixtures and maintenance area drains extended to a new sewage ejector which pumps to the city sewer
- Office HVAC consists of gas fired supply units containing DX cooling. Heated Service area heating and ventilating consists of Infra-Red heaters, direct gas fired make-up air unit and exhaust systems.
- Electrical systems consist of the following:
- Lighting and power to office area
- Exterior wall and pole mounted lighting, security gate, and fuel dispenser.
Prior Project Examples of Principals
United States Air Force Maintenance Facility - Minneapolis, Minnesota
- Construct a new Vehicle Maintenance Facility, which includes oil and grease bays, wash bays, welding areas, etc.
- Construct a new Fueling Maintenance Facility, which includes special systems (plumbing, heating, and ventilating) to enable servicing of refueling vehicles.
Vehicle Maintenance Facility - Edina, Minnesota
- Provide ventilation modifications to existing facility to meet new codes.
Monticello Vehicle Maintenance - Monticello, Minnesota
- Provide heating, ventilating, and plumbing systems for a maintenance shop, wash bay, and storage facility. Systems include welding exhaust and compressed air.