| Medical
VA Medical Center Radiology Area Modifications - Minneapolis, Minnesota:
Remodel the existing Radiology Suite for improved operation.
- Mechanical systems include extending the existing HVAC and exhaust systems, new plumbing fixtures, medical gases, and fire protection.
- Electrical systems include extending the existing lighting, power, communications, and medical gas alarm systems.
Wellness Center - Hudson, Wisconsin:
- Tenant improvements to construct a wellness center / chiropractic facility.
- Remodel the existing area with a new HVAC system and plumbing system.
- Provide "As-Built" documents for construction.
Prior Project Examples of Principals
V A Medical Center Radiology Area Modifications - Minneapolis, Minnesota:
Remodel of Four Existing Patient Care Rooms:
- Remodel four existing patient care rooms into TB isolation rooms.
- Modify the air supply and air exhaust systems to maintain a negative pressure in the TB patient room in relationship to the ante room and the corridor.
- Achieve energy conservation through the ability to switch from TB isolation room (negative) to a typical patient room (natural) relationship.
- Room pressure relationships monitored and alarmed at the nurses’ station.
Remodel of the Existing In-Patient Pharmacy:
- Modify plumbing, fire protection, air supply, return and exhaust systems as required for an automated pharmacy dispensing unit.
St. John's Hospital - Maplewood, Minnesota
- Project Engineer / Project Manager for a $46 million dollar addition to and remodeling of the existing hospital.
- Provide plumbing, medical gas, fire protection, heating ventilating and air conditioning systems including a new boiler and chiller plant interconnected to the existing plants.
- Provide new medical air and vacuum systems interconnected with existing systems.

Hennepin County Medical Center - Minneapolis, Minnesota
- Remodel existing patient rooms in the burn unit to provide a sterile atmosphere.
- Modify the existing air supply and exhaust system.
Metropolitan Mount Sinai Hospital - Minneapolis, Minnesota
- Provide a study of the existing chilled water distribution system for Metropolitan Mount Sinai Hospital and Hennepin County Medical Center.
- Install a 5,500 ton high-pressure steam turbine chiller interconnected with 5,000 ton of existing chiller capacity.
- Provide new condenser and primary water pumps.
- Modify piping, valving, and pumps in the distribution system.
- Modify the existing boilers from 125# to 250# steam pressure.